1. Brief Introduction to its Applications
The advanced technique of FTD Automation Instruments has been introduced to produce this flow meter measuring gas mass flow. Traditional flow meters need to adopt temperature and pressure compensation for measurement of fluid mass flow, whereas this flow meter can directly measure fluid mass flow without requiring temperature and pressure compensation. Its conspicuous features are as follows: direct trade settlement, no movable components, small pressure loss, wide range ratio, high accuracy, high reliability, simple installation and convenient operation. It is extensively used in the industries such as petroleum, chemical industry, medical industry, heat power plant and environmental protection etc.
2. Operating Principle
The thermal gas mass flow meter employs thermal diffusion principle. The thermal diffusion technique is that of excellent performance and high reliability under severe conditions. The typical sensing elements include two thermal resistances (platina RTD); one is a velocity sensor and the other is a temperature sensor for automatic compensation for gas temperature variation. When the two RTDs are placed in medium, the velocity sensor is heated to a constant difference in temperature above ambient temperature, and the temperature sensor is used to respond to the medium temperature. If gas velocity increases, the heat quantity transmitted to the medium from the sensor will increase, so there is a need for more supply of power, whereas the power for electronic elements to heat RTD is corresponding with mass flow to a certain extent.
3. Data
Accuracy | ±1% reading; ±0.5% full range |
Repeatability | ±0.5% of full range |
Turn down ratio | Normal 100:1; it is decided by calibrated flow range |
Upper Limit of Range | 80 Nm/s (air,20℃,101.33kPa) |
Lower Limit of Range | 0.05Nm/s (air,20℃,101.33kPa) |
Size | Ø6~ Ø6000 |
Pressure Range | Negative Pressure, 0~1.0MPa,0~1.6MPa,0~2.0MPa,0~3.0MPa |
Medium Temperature | -20~60℃,60~100℃,100~150℃,150~200℃,200~300℃ |
Medium | All kinds pure gas or mixed gas with fixed percentage, gas with dust, sand or moisture, corrosive gas |
Sensor Diameter | Ø3(standard), Ø4 |
Sensor Material | 316SST,hastelloy,titanium |
Probe Stem Diameter | Ø19(standard), Ø16, Ø12 |
Probe Stem Material | 316SST,hastelloy, |
Power supply | 24VDC/400mA or 220VAC/2W |
Output | 4-20mA DC, max load 1000Ω;RS485 |
Display | LED; four digits instantaneous flow , eight digits totalized flow |
Correction | 16 non-linearity correction |
Type | Remote type: transmitter + flow totalizer Integral type: transmitter with integral totalzier |
Connection type | In-line type and plug-in type |
Alarm | 1-2 relay output,3A/220VAC,3A/30VAC,settable |
Protection level | IP65 |
Explosive proof | Ia IICT65,ExdII CT4 |
Lifetime | 5 years |